A 5 m RSJ opening: checking headroom and the span used in calculations

Follow a 5 m deflection example, distinguish opening width from model span and prepare a dimensioned ceiling detail for the structural designer.

“Five metres” can describe the opening you want to see when the room is finished, the distance between the beam supports in a calculation, or the steel length on an order. Which one is written on your drawing? The difference matters before anyone can price or specify a beam.

Mark the three dimensions separately

On a sketch through the opening, mark the clear width between finished faces. Ask the designer to show where the beam bears or connects at either end and which distance they have used for analysis. Record the fabrication length separately against the beam mark. None of these dimensions by itself tells you what section to order.

If the ceiling needs to stay flush, give the designer a vertical dimension as well. Measure to the proposed finished ceiling line and identify services that already occupy that space. A depth taken from a steel catalogue describes bare steel. A connection or fire protection detail can require space outside that outline.

What a 5 m calculation actually says

Take an illustrative simply supported 203 × 133 × 25 UB. Assume its support centres are exactly 5 m apart and the total uniform service load is 12 kN/m, including beam weight. The total force is 60 kN. In this symmetrical model each end carries a 30 kN reaction and the maximum bending moment is 37.5 kNm.

For the major-axis second moment of area of 2,340 cm⁴ and elastic modulus of 210,000 N/mm², the calculated midspan deflection is 19.87 mm. A comparison limit of span/360 gives 13.89 mm. The example exceeds that chosen target. The engineer determines the actual load, support model and movement criteria for the building. These assumed values do not specify a section for a five-metre opening.

To reproduce the numbers, use the deflection calculator, select the section above and enter 12 as the total line load. The source row, unit conversions and equation are in the section reference. The separate section comparison tool adds self-weight to its input, so entering 12 there describes a slightly heavier load.

How to discuss a headroom conflict

What the drawing showsWhat to ask the design team
A ceiling level but no beam section through itWhere is the lowest finished surface once the connection and protection are included?
A beam close to a duct or pipeCan both be accommodated in the issued arrangement, and who coordinates the changes?
A beam shown flush with the floor zoneHow do the supports, connections and restraint fit at each end?
Different dimensions on survey and structural drawingsWhich revision and site dimension will the fabricator use?

Keep these questions with the marked section drawing. An enclosure does not automatically provide structural restraint. If the proposed depth clashes with the room layout, ask the engineer to reconsider the whole arrangement before the fabricator cuts steel. A wider flange or a different section of similar depth cannot be selected from a photograph.

Earlier size suggestions on this page have been withdrawn. A chartered structural engineer must check the loads, strength, stability, supports and connections for the actual building, and the work needs the applicable Building Control approval.