RSJ span and deflection comparison table

See how the same UB deflects at two support-centre spans. Compare sections using one uniform load per metre and the British Steel section data.

How to use this tool

  1. Enter your span between support centres. Tick the second-span option to compare two measurements.
  2. Enter uniform service load excluding beam weight and a deflection comparison ratio.
  3. Read across one section row. The extra column shows how its deflection changes with the second span at the same load per metre.

RSJ deflection comparison table

Simply supported beam, major-axis bending, uniform service load. This model does not establish a safe load or approve a beam size.

Beam self-weight is added automatically for each section. The ratio is an illustrative target you choose, not a universal Building Regulations limit.

Professional design required. A chartered structural engineer must determine loads, effective span, restraints, suitable section and project-specific limits. Obtain the required Building Control approval before structural work.

Data: British Steel UB datasheet, 21 July 2026. Section values, formulas and limitations.

Compare two spans in one row

Enter 4 m as the first span and 5 m as the second. Leave the line load at 12 kN/m excluding beam weight. In the 203 × 133 × 25 row the first deflection is about 8.31 mm. The second is about 2.44 times as large. The target column applies to the first span.

Read the guide to span tables

Questions and limitations

Why does deflection change so much with span?

At a constant line load, calculated deflection is proportional to the fourth power of the span. Changing from 4 m to 5 m multiplies the result by about 2.44. The comparison target shown is for the first span. Neither result establishes a safe span.

Where do the section properties come from?

The tools share data transcribed from the British Steel Universal Beams datasheet dated 21 July 2026. See the methodology page for values, formulas and sources.

Can I model a point load, cantilever or continuous beam?

No. This model is restricted to a simply supported beam under a full-span uniformly distributed service load. Obtain project-specific calculations from a chartered structural engineer.

Data and editorial responsibility

Published by Krystian Welcel, a software developer. These tools have not received an independent structural engineering review. Read the data sources and calculation method.

Structural work must be designed by a chartered structural engineer and receive the applicable Building Control approval. These educational calculations are not construction specifications.